V800 Cabinets and Accessories
Overview
Siemon's V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable space on each side of the equipment rails for cable management, PDU mounting or connectivity on both the front and rear of the cabinet. The V800 cabinet is ideal for high-density data center environments, enabling increased cabling and equipment density while providing excellent accessibility and thermal efficiency. All of these features are integrated into a full-featured modular enclosure that is equally effective as a standalone network and server cabinet or in a multi-unit bayed configuration, offering a simple, scalable expansion path in any data center.
- Lightweight Stability Design provides an extremely stable, high-capacity cabinet without excessive weight
- Zero-U Modularity Half-height Zero-U panels can be mounted in any of the four quadrants (top left, bottom left, top right and bottom right) of both the front and rear of the cabinet
- Full Accessibility Doors Quick release, field reversible single piece front and split rear doors
- Integrated Side Panel Grounding Spring loaded grounding clips eliminate need for dedicated grounding conductors
- High-Flow Doors Contoured high density perforated door provides up to 71% perforation exceeding major IT equipment air flow requirements
- Fully Adjustable Equipment Rails Can be readily configured to support any range of equipment depths
Benefits
- The V82A cabinet is exactly 1200mm deep, allowing for full access to adjacent tiles immediately in front or in back of placed cabinets and provides full 1.2m aisle spacing as specified within ISO/IEC 14763-2 and EN 50600-2-4.
- The cabinet lid includes four integrated brush guards for cables to enter the cabinet without compromising thermal integrity.
Specifications
Dimensions | |
Height* | 42U: 2013mm (79.25 in.) 45U: 2146mm (84.5 in.) 48U: 2280mm (89.75 in.) |
Width | 800mm (31.5 in.) |
Depth - External (Door-to-Door) | V81A: 1000mm (39.37 in.) V82A: 1200 mm ( 47.24 in) |
Depth - Usable (Rail to Rail Max.) | V81A: 806mm (31.8 in.) V82A: 1006mm (39.6 in.) |
Weight** | 42U V81A: 111kg (245 lbs.)/V82A: 126kg (278 lbs.) 45U V81A: 116kg (256 lbs.)/V82A: 131kg (289 lbs.) 48U V81A: 121kg (267 lbs.)/V82A: 136kg (300 lbs.) |
Load Rating | Static: 1000kg ( 2205 lbs ) Dynamic: 714kg ( 1575 lbs ) |
Base Type | Open |
Color | Graphite Black (RAL 9011), Signal White (RAL 9003), Light Grey (RAL 7035) |
% Door Perforation | 71% |
U Space Identification | Yes (bottom-to-top) |
Lid Cable Access Openings | V81A: 3 large; (4) 63x406mm (2.5x16 in.) integrated brush guards V82A: 4 large; (4) 63x406mm (2.5x16 in.) integrated brush guards |
Material | CRS of varying thickness |
Finish | Textured Powder Coat |
Standards Compliance | UL 60950-1 Ed2.0, EIA/ECA-310-E, IP20 |
* Nominal height with stabilizing brackets;
** Does not include packaging
Part Numbers
- 1) V800 Cabinet
- V8(X)A-(X)(X)(X)(X)(X)1-(XX) V800 Cabinet, Black. Includes (4) leveling feet, (50) M6 cage nuts and (2) stabilizing brackets.
- 2) V800 Cabinet Accessories
- CN-M6-50 M6 Cage Nuts, Bag of 50
- HCM-4-(X)U (Picture) RouteIT 19 in. Horizontal Cable Manager with 4 in. Fingers
- HCM-6-(X)U (Picture) RouteIT 19 in. Horizontal Cable Manager with 6 in. Fingers
- PNL-BRSH-1 (Picture) 19 in. Brush Guard Panel, 1U
- PNL-TBLNK010-1S (Picture) 19 in. Snapfit Thermal Blanking Panel, 1U, Pkg of 10
- PNL-TBLNK100-1S (Picture) 19 in. Snapfit Thermal Blanking Panel, 1U, Pkg of 100
- RS-VCM (Picture) 1/4-turn Hook and Loop Cable Managers, Box of 10. Can be installed in Vertical Patching Channels w/Fingers
- V-SHV1-(XX)-1U (Picture) 4-post, Adjustable Shelf, Vented, 559-787mm (22-31 in.), Black, 1U
Use (XX) to specify color. 01 = black, 2 = white, 4 = gray
- V-SHV2-(XX)-1U (Picture) 4-Post, adjustable shelf, vented, 787-1016mm (31- 40 in.), 1U, black
Use (XX) to specify color. 01 = black, 2 = white, 4 = gray
- V-TRAY-100-(X)-(XX) (Picture) 100mm (3.9 in) V600/V800 Vertical Cable Tray, Set of 2, Black
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V-TRAY-150-(X)-(XX) (Picture) 150mm (5.9 in) V600/V800 Vertical Cable Tray, Set of 2, Black
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V-TRAY-300-(X)-(XX) (Picture) 300mm (11.8 in) V600/V800 Vertical Cable Tray, Set of 2, Black
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V-W-(X) (Picture) V600/V800 Casters (set of four)
Use (X) to specify color. Blank = black, 2 = white, 4 = gray
- V1A-S-(X)-(XX) (Picture) V600/V800 1000mm (39.4 in.) split side panels, black, set of 2
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V2A-S-(X)-(XX) (Picture) V600/V800 1200mm (47.2 in.) split side panels, black, set of 2
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-BLNK-(X)-(XX) (Picture) Half-height Zero-U Vertical Blanking Panel. Used to block off unused Zero-U spaces to prevent re-circulation of air.
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-BRSH-(X)-(XX) (Picture) Half-height Zero-U Vertical Brush Guard Panel
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-DRA-(X)-(XX) (Picture) V800 Full Vented Door, Black
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-DRB-(X)-(XX) (Picture) V800 Split Vented Doors, Black, set of 2
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-DRC-(X)-(XX) (Picture) V800 Split Solid Doors, Black, set of 2
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-LD-(X) (Picture) V800 lid divider panel, set of 2, 107mm (4.2 in.) high Used to create cable pathways on top of bayed cabinets
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
- V8A-PDU-F1-(X)-(XX) (Picture) Full-height Zero-U Vertical PDU Panel Full length brackets support tool-less mounting of one (1) vertical rack mount PDU with a maximum width of 86.4mm (3.4 in.) and 1.24m (49 in.), 1.56m (61.25 in.) or 1.65m (64.75 in.) O.C. mounting buttons
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-R-(X)-(XX) (Picture) V800 equipment mounting rail, black, set of 2
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-VPC145-(X)-(XX) (Picture) Half-height Zero-U Vertical Patching Channel with D-Ring Managers
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-VPC4-(X)-(XX) (Picture) Half-height Zero-U Vertical Patching Channel with 4 in. Fingers and Cover
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-VPC6-(X)-(XX) (Picture) Half-height Zero-U Vertical Patching Channel with 6 in. Fingers and Cover
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- V8A-VPP2U-(X)-(XX) (Picture) Half-height Zero-U Vertical Patch Panel, 2U. Includes (8) M6 cage nuts Mounts 2U of standard 19 in. panels or PDUs in vertical orientation
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U- VA-VPA-BAY-(X) (Picture) VersaPOD-to-V600/V800 Baying Kit. Secures (1) VersaPOD cabinet to (1) V600/V800 cabinet.
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
- VP-143 (Picture) 1/4-turn Hook and Loop Cable Managers, 88.9x44.5mm (3.50x1.75 in.) Can be installed in Vertical PDU/Cable Management Brackets.
- VP-145 ¼-Turn D-Ring Cable Manager (box of 10), 127.0x88.9mm (5.00x3.50 in.). Can be installed in Vertical Management Trays only.
- VP-DUCT1-(X)* (Picture) Adjustable Height Vertical Exhaust Duct, 516-923mm (20-36 in.)
Use (X) to specify color. Blank = black, 2 = white, 4 = gray
- VP-DUCT2-(X)* (Picture) Adjustable Height Vertical Exhaust Duct, 913-1320mm (36-52 in.)
Use (X) to specify color. Blank = black, 2 = white, 4 = gray
- VP-FAN (Picture) Top-Mount Cooling Fan Panel. 3 Fans x 110CFM, 120VAC w/NEMA 5-15P plug, UL Listed
- VP-FAN-220 (Picture) Top-Mount Cooling Fan Panel. 3 Fans x 110CFM, 220VAC w/C13 plug, UL Listed
- VP-GRD (Picture) Grounding Kit. Includes ground bar, ground wire, mounting hardware and accessories (capacity to support all required grounding connections for a single cabinet)
- VP-SPL (Picture) 1/4-Turn Fiber Management Spool, Bag of 5. Can be installed in Vertical Patching Channels w/Fingers
- VP-T3 (Picture) Brush Guard, Large For large center top panel cable openings
- VPA-SPAN-(X) (Picture) Adjustable Depth Cable Trough Extends from 555mm (21.9 in.) to 911mm (35.9 in.) 81mm (3.2 in.) wide; 65mm (2.6 in.) high Used to route cables between the front and rear of cabinets. Mounts between Vertical Patching Channels mounted to front and rear of cabinets.
Use (X) to specify color. 1 = black, 2 = white, 4 = gray
Use (XX) to specify cabinet height: 42 = 42U, 45 = 45U, 48 = 48U
- Note:
- * Vertical exhaust ducts are compatible with 1200mm deep cabinets only. Solid doors should be specified for cabinets using exhaust ducts.
Because we continuously improve our products, Siemon reserves the right to change specifications and availability without prior notice
Need Help?
Email:
SIS Customer Service
SIS Sales
Customer Service:
1-860-945-4213
(8AM to 5PM EST)
Sales:
1-860-945-5856
Technical Support:
1-860-945-4390
eNewsletter Signup
Sign up to receive the latest SIS product news and information.
Tweets by @SiemonIS
Follow SIS