Google Translate

Worldwide | United Kingdom

XGLO and LightSystem LS0H-3 Indoor/Outdoor Tight Buffer (International)

XGLO and LightSystem LS0H-3 Indoor/Outdoor Tight Buffer (International)Enlarge this image

Overview

Siemon LSOH (IEC 60332-3) indoor/outdoor tight buffer cables are ideal for data centers, campus and building backbones. Siemon fibre optic cables are offered in XGLO and LightSystem configurations supporting high-speed applications such as Gigabit Ethernet, 10 Gigabit Ethernet, Gigabit ATM and Fibre Channel.

RoHS Compliant

Part of the XGLO cabling system.

Part of the LightSystem cabling system.


Specifications

Standards Compliance

XGLO Singlemode, OS2

  • ISO/IEC 11801:Ed 2.0 Amendment:1:2008
  • ANSI/TIA/EIA-568-C.3
  • ANSI/TIA-598-C
  • Telcordia GR-409-CORE
  • ITU-T G.652.C/D
  • IEC 60332-3
    IEC 60332-1-2 (Single strand),
    IEC 60754-2 (Acid gas),
    IEC 61034-2 (Smoke density)

XGLO (550) Multimode, 50/125, OM4

  • ISO/IEC 11801:2002 OM3
  • ISO/IEC 11801:2002 Ammendment 2 OM4
  • ANSI/TIA/EIA-568-C.3
  • ANSI/TIA-598-C
  • ANSI/TIA-492 AAAD
  • IEC 60793-2-10 Fiber Type A1a.3
  • Telcordia GR-409-CORE
  • IEC 60332-3
    IEC 60332-1-2 (Single strand),
    IEC 60754-2 (Acid gas),
    IEC 61034-2 (Smoke density)

XGLO Multimode (300) 50/125, OM3

  • ISO/IEC 11801:2002 OM3
  • ANSI/TIA/EIA-568-C.3
  • ANSI/TIA-598-C
  • ANSI/TIA-492 AAAC
  • Telcordia GR-409-CORE
  • IEC 60332-3
    IEC 60332-1-2 (Single strand),
    IEC 60754-2 (Acid gas),
    IEC 61034-2 (Smoke density)

LIGHTSYSTEM Multimode 50/125,OM2; 62.5 OM1

  • ISO/IEC 11801:2002 OM1 (62.5/125)
  • ISO/IEC 11801:2002 OM2 (50/125)
  • ANSI/TIA/EIA-568-C.3
  • ANSI/TIA-598-C
  • ANSI/TIA-492 AAAB
  • Telcordia GR-409-CORE
  • IEC 60332-3
    IEC 60332-1-2 (Single strand),
    IEC 60754-2 (Acid gas),
    IEC 61034-2 (Smoke density)


Other Information/Photos

Applications Support

XGLO Singlemode, OS2

Application Distance (m)
10GBASE-L (1310 nm) 8,000
10GBASE-E (1550 nm) 30,000
10G Fibre Channel (Serial-1310 nm) 10,000
10G Fibre Channel (WDM-1310 nm) 10,000
1000BASE-LX (1300 nm) 5,000
Fibre Channel 266/1062 (1300 nm) 10,000
ATM 52/I55/622 (1300 nm) 15,000

XGLO (550) Multimode, 50/125, OM4

Application Distance (m)
10GBASE-SX (850 nm) 550
10GBASE-LX4 (1300 nm) 300
1000BASE-SX (850 nm) 1000
1000BASE-LX (1300 nm) 600
Fibre Channel 266 (1300 nm) 1,500
ATM 622 (1300 nm) 500
ATM 155 (1300 nm) 2,000
ATM 52 (1300 nm) 3,000
FDD1 (Original-1300 nm) 2,000
100BASE-FX (1300 nm) 2,000

XGLO Multimode (300) 50/125, OM3

Application Distance (m)
10GBASE-SX (850 nm) 300
10GBASE-LX4 (1300 nm) 300
1000BASE-SX (850 nm) 900
1000BASE-LX (1300 nm) 600
Fibre Channel 266 (1300 nm) 1,500
ATM 622 (1300 nm) 500
ATM 155 (1300 nm) 2,000
ATM 52 (1300 nm) 3,000
FDD1 (Original-1300 nm) 2,000
100BASE-FX (1300 nm) 2,000

LIGHTSYSTEM Multimode 50/125,OM2; 62.5 OM1

Application Distance (m)
10GBASE-SX (850 nm)
50/125µm 82
62.5/125µm 26
1000BASE-SX (850 nm)
50/125µm 550
62.5/125µm 275
1000BASE-LX (1300 nm) 550
Fibre Channel 266 (1300 nm) 1,500
ATM 622 (1300 nm) 500
ATM 155 (1300 nm) 2,000
ATM 52 (1300 nm) 3,000
FDDI (Original-1300 nm) 2,000
100BASE-FX (1300 nm) 2,000


Part Numbers

XGLO Multimode 50/125 OM3, OM4, Singlemode 0S2, LightSystem Multimode 62.5/125 OM1, 50/125 OM2
9GD(X)H004C-(XXXX)M  Fibre Count = 4, Construction = 1 tube of 4 fibres
9GD(X)H006D-(XXXX)M  Fibre Count = 6, Construction = 1 tube of 6 fibres
9GD(X)H008E-(XXXX)M  Fibre Count = 8, Construction = 1 tube of 8 fibres
9GD(X)H012G-(XXXX)M  Fibre Count = 12, Construction = 1 tube of 12 fibres
9GD(X)H016K-(XXXX)M  Fibre Count = 16, Construction = 1 tube of 16 fibres
9GD(X)H024L-(XXXX)M  Fibre Count = 24, Construction = 1 tube of 24 fibres
9GD(X)H048G-(XXXX)M  Fibre Count = 48, Construction = 4 tubes of 12 fibres
9GD(X)H072G-(XXXX)M  Fibre Count = 72, Construction = 6 tubes of 12 fibres

Use 1st (X) to specify fiber type: 5 = 50/125µm, 6 = 62.5/125µm, 5 = 50/125µm Laser Optimized, 8 = Singlemode

Use (XXXX) to specify class performance: G101 = OM1 62.5µm, T101 = OM2 50µm,T301 = OM3 50µm Laser Optimized,T501 = OM4 50µm Laser Optimized, E201 = OS2 Singlemode

Note:
Note: Contact Siemon Customer Service for cables available in fixed reel lengths. (unit of measure) m=meters

Because we continuously improve our products, Siemon reserves the right to change specifications and availability without prior notice


Need Help?

Ask Siemon

info_uk@siemon.com

+44(0)1932 571 771 (UK)
8am-5:00pm (»Worldwide)


Innovate Magazine
Cisco and Siemon

Cisco Technology Developer Partner


See Siemon in Cisco Marketplace:

Category 7 Cabling?
Cat 7 for the real world Articles and case studies 48 pages
» Learn more

Case Studies - See how Siemon is connecting the world to a higher standard
Find Partners

» Find Siemon Authorized Distributors

» Find Certified Installers & Consultants