Home    Products    Solutions    Services    Support    Company  

Comparison Of ‘568-b.3 Versus ‘11801:2002 2nd Edition Fiber Cabling Performance Specifications

’568-B Series

Horizontal Link Insertion Loss 2.0 dB at 850nm or 1300nm
Horizontal Link Insertion Loss With/CP 2.75dB @ 850nm or 1300nm
Centralized Link Insertion Loss 3.3 dB @ 850nm or 1300nm
based on three connector pairs
Centralized Plus Open Office CP Link Insertion Loss 4.1 dB @ 850 or 1300nm
based on three connector pairs
Backbone Link Insertion Loss = Cable Atten + Connector Insertion Loss + Splice Insertion Loss
Connector Insertion Loss 0.75 dB
Splice Insertion Loss 0.3 dB

Cable Atten

3.5 dB/km at 850nm for
62.5/125µm and 50/125µm

Cable Atten

1.5 dB/km at 1300nm for
62.5/125µm and 50/125µm

Cable Atten

0.5 dB/km for singlemode
outside plant cable

Cable Atten

1.0 dB/km for singlemode
inside plant cable

Channel Attenuation
dB

Channel

Multimode

Singlemode

 

850nm

1300nm

1310nm

1550nm

OF-300

2.55

1.95

1.80

1.80

OF-500

3.25

2.25

2.00

2.00

OF-2000

8.50

4.50

3.50

3.50

Multimode Optical Fiber Modal Bandwidth (Overfilled Launch)

’568-B Series

Bandwidth

160 MHz-km at 850nm
for 62.5/125µm

Bandwidth

500 MHz-km at 850nm
for 50/125µm

Bandwidth

500 MHz-km at 1300nm
for 62.5/125µm and 50/125µm

Note: Additional performance specifications for 50/125µm cables are provided in ANSI/TIA/EIA-568-B.3-1.These requirements are harmonized with fiber type ‘OM3’ as specified in ISO/IEC 11801:2002 2nd Edition.

’11801:2002 2nd Edition

Bandwidth

200 MHz-km at 850nm for
62.5/125µm and 50/125µm (OM1)

Bandwidth

500 MHz-km @ 850nm for
62.5/125µm and 50/125µm (OM2)

Bandwidth

1500 MHz-km @ 850nm for
62.5/125µm and 50/125µm (OM3)

Bandwidth

500 MHz-km at 1300nm for
62.5/125µm and 50/125µm
(OM1, OM2 and OM 3)

Note: Fiber type OM3 specified in ISO/IEC 11801:2002 2nd Edition, requires laser launch bandwidth of 2000 MHz-km at 850nm. This requirement is assured by testing differential modal delay (DMD).